Find the most up-to-date version of ASTM F134 at GlobalSpec. UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS. SIGN UP TO SEE MORE. First Name. ... DETERMINING HERMETICITY OF ELECTRON DEVICES WITH A HELIUM MASS SPECTROMETER LEAK DETECTOR inactive Buy Now. Details. History. Organization: …
Description: The Agilent HLD PR02 Leak Detector uses a mass spectrometer tuned to detect helium, which is used as a tracer gas to locate and/or measure very small leaks in enclosed devices or systems. The compact and portable HLD PR02 is both a precise instrument and a Computer Interface Options: Serial Interface
Find the most up-to-date version of MIL-STD-1441 at GlobalSpec. UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS. SIGN UP TO SEE MORE. First Name. ... This standard covers various types and classes of helium leak detection equipment for use in testing the inert components of chemical munitions for leaks, and …
Re: Helium Leak Detectors and Helium requirements. 05/18/2007 4:55 PM. Hi there; Helium is helium there-for it should work. It only cost $15.00 at the local party supply house. Used for blowing up balloons; Helium Works well on my classic Veco MS9. Mr X. PS you can use it for laser mix as well. Register to Reply.
Find the most up-to-date version of SEMI F106 at GlobalSpec. UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS. SIGN UP TO SEE MORE. First Name. ... TEST METHOD FOR DETERMINATION OF LEAK INTEGRITY OF GAS DELIVERY SYSTEMS BY HELIUM LEAK DETECTOR active, Most Current Buy Now. Details. History. …
Find the most up-to-date version of ASTM UOP1024-18 at GlobalSpec. UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS. SIGN UP TO SEE MORE. First Name. Last Name. Email Address. Company.
Description: The Agilent HLD MR15 Leak Detector uses a mass spectrometer tuned to detect helium, which is used as a tracer gas to locate and/or measure very small leaks in enclosed devices or systems. This detector is both a precise instrument and a robust workhorse, featuring. Computer Interface Options: Serial Interface.
Description: The Agilent HLD MR15 Leak Detector uses a mass spectrometer tuned to detect helium, which is used as a tracer gas to locate and/or measure very small leaks in enclosed devices or systems. This detector is both a precise instrument and a robust workhorse, featuring an easy-to-use. Computer Interface Options: Serial Interface.
HLD BR15 Bench Helium Leak Detector. from Agilent Technologies - Vacuum Products. The Agilent HLD BR15 Benchtop Leak Detector uses a mass spectrometer tuned to detect helium, which is used as a tracer gas to locate and/or measure very small leaks in enclosed devices or systems. The HLD BR15 is both a precise instrument and a robust workhorse ...
Find Helium Detector related suppliers, manufacturers, products and specifications on GlobalSpec - a trusted source of Helium Detector information.
Products/Services for Portable Helium Gas Detectors Gas Sensors - (567 companies) ...test methods that apply to portable, transportable, and fixed devices for the detection and measurement of flammable gas or vapor concentrations in air.
ASTM International - ASTM F134-85(1990) Test Methods for Determining Hermeticity of Electron Devices with a Helium Mass Spectrometer Leak Detector (Withdrawn 1996)
Gas Instruments - Restek®Electronic Leak Detector. Supplier: Restek. Description: -5, red LED Nitrogen, 1.4 x 10-3, yellow LED Argon, 1.0 x 10-4, yellow LED Carbon dioxide, 1.0 x 10-4, yellow LED Gas detection limits measured in atm cc/sec. Avoid using liquid leak detectors on a GC! Liquids can be drawn into the system and/or into the leak ...
Find the most up-to-date version of ASTM UOP1024-18 at GlobalSpec. UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS. SIGN UP TO SEE MORE. First Name. ... (GC) equipped with a pulsed discharge helium ionization detector (PDHID). The instrument is preconfigured and capable of determining typical impurities in polymer …
Gas Instruments - O2 Industrial Gas Detector -- CM-902. Supplier: CO2Meter. Description: (O2) Warm-Up Time: <60 seconds at 22°C Calibration: Manual with test gas or factory calibration Dimensions: 8.25 in x 6.25 in x 3 in Weight: 1.5 lbs (monitor only) Sensor Life Expectancy: Instrument Type: Detector. Supplier Catalog.
scope: 1.1 This practice covers procedures for testing and locating the sources of gas leaking at the rate of 1 × 10 −7 Pa m 3 /s (1 × 10 −8 Std cm 3 /s)3 or greater. The test may be conducted on any device or component across which a pressure differential of helium or other suitable tracer gas may be created, and on which the effluent side of the …
This SAE Standard provides the testing and functional requirements guidance necessary for a leak detection device that uses any non-A/C refrigerant tracer gas, such as helium or a nitrogen-hydrogen blend, to provide functional performance equivalent to a refrigerant electronic...
Find the most up-to-date version of UOP1024 at GlobalSpec. UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS. SIGN UP TO SEE MORE ... Determination of Trace Permanent Gases in Polymer Grade Ethylene & Propylene by Gas Chromatography-Pulsed Discharge Helium Ionization Detector active, Most Current Buy …
The Agilent HLD MD15 Dry Leak Detector uses a mass spectrometer tuned to detect helium, which is used as a tracer gas to locate and/or measure very small leaks in …
ORS manufactures the HSHLD® Model 310 High Sensitivity Helium Leak Detection System, a Quadrupole Mass Spectrometer system for High Sensitivity Helium Leak Rate measurement to qualify your product to the latest, tighter leak rate requirements of Mil-Std-883, Method 1014.
Oneida Research Services, Inc. Description. ORS manufactures the HSHLD® Model 310 High Sensitivity Helium Leak Detection System, a Quadrupole Mass Spectrometer …
E-Labs, Inc. Helium Leak Detection CONTACT E-LABS. Helium Leak Detection Testing. E-Labs has multiple Varian, Mass Spectrometer helium leak detectors for finding leaks as small as 1x10-10 cc/sec. We are capable of leak testing to pressures up 20,000 psi using nitrogen and 80,000 psi using liquids. About E-Labs. E-Labs is a Full Service Testing …
We re currently looking for a helium leak detector capable of measuring a leak rate not to exceed 9x10 7 cc sec Helium This equipment is to leak check a potted switch. We had a product demo... CR4 - The Engineer's Place for News and Discussion ®
Everything leaks! This forty-minute webinar will describe the challenges of locating and measuring leaks. We'll compare leak detection technologies and methods with respect to sensitivity, time, and cost, and we'll explore helium tracer gas as a robust, sensitive and repeatable method of identifying leaks and determining leak rate.
Supplier: Agilent Technologies - Vacuum Products. Description: The Agilent HLD BR30 Benchtop Leak Detector uses a mass spectrometer tuned to detect helium, which is used as a tracer gas to locate and/or measure very small leaks in enclosed devices or systems. The HLD BR30 is both a precise instrument and a robust workhorse, featuring.
If one searches the technical and patent literature for " sniffers," one typically finds leak -detection equipment fitted with a high- length-to-diameter-ratio hose having a hand-held, pointed tip16 . … by 1-2 m long and is intended for the detection of leaking gases such as helium . The detector was a thermocouple inside a simple ...
Find the most up-to-date version of ASTM D8098-17 at GlobalSpec. UNLIMITED FREE ACCESS TO THE WORLD'S BEST IDEAS. SIGN UP TO SEE MORE ... Standard Test Method for Permanent Gases in C 2 and C 3 Hydrocarbon Products by Gas Chromatography and Pulse Discharge Helium Ionization Detector 1.1 This test method …